Monthly electricity usage to solar panel count

Direct answer: at 4.5 peak sun hours and 20% system losses, 1,000 kWh/month needs about 9.1 kW of required capacity, rounded to 23 x 400W panels. At 3,000 kWh/month, the same assumptions need about 27.4 kW, rounded to 69 x 400W panels.

500-3,000kWh/month covered
350W / 400W / 450Wpanel ratings compared
3.5 / 4.5 / 5.5peak sun hours/day
How to read each cell: recommended panel count, rounded-up DC system capacity, and approximate module footprint. The roof number is panel surface only. PVSize's roof-fit calculator assumes 75% of gross roof area is usable, so divide the table footprint by 0.75 for a first gross-roof check before local setbacks, access paths, obstructions, tilt, and layout.

Low-sun reference: 3.5 peak sun hours/day

Monthly use350W panels400W panels450W panels
500 kWh17 panels5.95 kW / 330 sq ft15 panels6.00 kW / 281 sq ft14 panels6.30 kW / 297 sq ft
1,000 kWh34 panels11.90 kW / 660 sq ft30 panels12.00 kW / 561 sq ft27 panels12.15 kW / 573 sq ft
1,500 kWh51 panels17.85 kW / 990 sq ft45 panels18.00 kW / 842 sq ft40 panels18.00 kW / 848 sq ft
2,000 kWh68 panels23.80 kW / 1,320 sq ft59 panels23.60 kW / 1,104 sq ft53 panels23.85 kW / 1,124 sq ft
2,500 kWh84 panels29.40 kW / 1,630 sq ft74 panels29.60 kW / 1,384 sq ft66 panels29.70 kW / 1,400 sq ft
3,000 kWh101 panels35.35 kW / 1,960 sq ft89 panels35.60 kW / 1,665 sq ft79 panels35.55 kW / 1,675 sq ft

Medium-sun reference: 4.5 peak sun hours/day

Monthly use350W panels400W panels450W panels
500 kWh14 panels4.90 kW / 272 sq ft12 panels4.80 kW / 225 sq ft11 panels4.95 kW / 234 sq ft
1,000 kWh27 panels9.45 kW / 524 sq ft23 panels9.20 kW / 431 sq ft21 panels9.45 kW / 446 sq ft
1,500 kWh40 panels14.00 kW / 776 sq ft35 panels14.00 kW / 655 sq ft31 panels13.95 kW / 658 sq ft
2,000 kWh53 panels18.55 kW / 1,029 sq ft46 panels18.40 kW / 861 sq ft41 panels18.45 kW / 870 sq ft
2,500 kWh66 panels23.10 kW / 1,281 sq ft58 panels23.20 kW / 1,085 sq ft51 panels22.95 kW / 1,082 sq ft
3,000 kWh79 panels27.65 kW / 1,533 sq ft69 panels27.60 kW / 1,291 sq ft61 panels27.45 kW / 1,294 sq ft

High-sun reference: 5.5 peak sun hours/day

Monthly use350W panels400W panels450W panels
500 kWh11 panels3.85 kW / 214 sq ft10 panels4.00 kW / 187 sq ft9 panels4.05 kW / 191 sq ft
1,000 kWh22 panels7.70 kW / 427 sq ft19 panels7.60 kW / 356 sq ft17 panels7.65 kW / 361 sq ft
1,500 kWh33 panels11.55 kW / 641 sq ft29 panels11.60 kW / 543 sq ft25 panels11.25 kW / 530 sq ft
2,000 kWh43 panels15.05 kW / 835 sq ft38 panels15.20 kW / 711 sq ft34 panels15.30 kW / 721 sq ft
2,500 kWh54 panels18.90 kW / 1,048 sq ft47 panels18.80 kW / 879 sq ft42 panels18.90 kW / 891 sq ft
3,000 kWh65 panels22.75 kW / 1,261 sq ft57 panels22.80 kW / 1,066 sq ft50 panels22.50 kW / 1,060 sq ft

Formula and assumptions

required kW = monthly kWh x 12 / (365 x peak sun hours x 0.80)

The panel count is required kW x 1,000 / panel watts, always rounded up to a whole panel. Installed DC capacity is the rounded panel count multiplied by panel wattage. All tables use 20% aggregate system losses, equal to an 80% planning efficiency.

Worked example: 1,000 kWh/month, 4.5 sun hours, 400W panels

Required capacity = 12,000 / (365 x 4.5 x 0.80) = 9.13 kW. Dividing by 0.40 kW per panel gives 22.83, so the planning count rounds up to 23 panels. Installed DC capacity is 9.20 kW and module footprint is about 431 sq ft.

Regional parameter check

Planning contextStarting sun-hoursLoss range to testWhat to verify locally
United States3.5-5.514%-22%Utility interval data, shading, net metering, snow, roof setbacks.
Australia4.0-5.514%-20%Export limits, inverter sizing, orientation, DNSP requirements.
United Kingdom2.5-3.518%-25%Seasonal yield, roof direction, shading, DNO/export constraints.

Check roof fit, then continue the project flow

The table answers the energy target. The Panel Count calculator checks how many selected modules fit the available roof and produces a shareable Solar Project Summary.

Related specific questions

Method note: values are deterministic planning calculations from the formula above, not measured production or installer quotes. Last reviewed July 18, 2026.